1 609 929 F23 - Buch Seite 3 Montag, 19. April 2004 8:27 08
Inserting Router Bits (see figure
Before any work on the machine itself, pull the
mains plug.
It is recommended to wear protective gloves
when inserting or replacing router bits.
Fold down chip shield 15.
Press spindle lock button 18 and keep de-
pressed. If required, turn the spindle by hand until
the lock engages.
Press the spindle lock button only when at a
standstill.
Insert router bit. The shank of the router bit must
be inserted at least 20 mm (shank length).
Tighten the tightening nut 17 with the open-end
spanner 25 (size 19 mm). Release the spindle
lock button 18.
Fold up chip shield 15.
Do not tighten the tightening nut of the
collet without a router bit inserted.
Dust/Chip Extraction
The dust that is produced while working can be
detrimental to health, inflammable or explo-
sive. Suitable safety measures are required.
Examples: Some dusts are regarded as carci-
nogenic. Use suitable dust/chip extraction and
wear a dust respirator.
Dust from light alloys can burn or explode. Al-
ways keep the workplace clean, as blends of
materials are particularly dangerous.
Mounting the Extraction Adapter
(see figure
)
B
Press the chip shield 15 together at the holding
fixture on the base plate and remove it.
Fasten
dust-collection
plate 12 with both knurled screws 26 and connect
vac via suction hose 28 (accessory).
When mounting the extraction adapter,
ensure correct mounting position!
For dust extraction, the 35-mm-Ø vacuum
hose 28 can be connected directly to the extrac-
tion adapter.
Clean the extraction adapter 27 regularly to en-
sure optimum dust extraction at all times.
The machine can be plugged directly into the re-
ceptacle of a Bosch all-purpose vacuum cleaner
with remote starting control. The vacuum cleaner
starts automatically when the machine is
switched on.
15 • 1 609 929 F23 • 04.04
)
A
adapter 27
to
base
English - 3
The vacuum cleaner must be suitable for the ma-
terial to be worked.
When vacuuming dry dust that is especially detri-
mental to health or carcinogenic, use a special
vacuum cleaner.
Initial Operation
Observe correct mains voltage: The voltage of
the power source must agree with the voltage
specified on the nameplate of the machine.
Equipment marked with 230 V can also be con-
nected to 220 V.
Switching On and Off
For starting operation of the machine, actuate
the lock-off button 20 first, and then press and
hold the On/Off switch 23 afterwards.
POF 1300 ACE: A lamp lights out the routing.
To switch off the machine, release the On/Off
switch 23.
POF 1300 ACE: The lamp slowly goes out.
Speed Preselection
The required speed can be preselected with the
thumbwheel 22 (also while running).
1 – 2 = low speed
3 – 4 = medium speed
5 – 6 = high speed
The required speed is dependent on the material
and can be determined by practical testing.
After longer periods of working at low speed, al-
low the machine to cool down by running it for ap-
prox. 3 minutes at maximum speed with no load.