MANUEL D'INSTALLATION
CA-A470-A
2-Door expansion module
The reader LEDs can be used to verify the reader's connections and programming. If no fl ashing occurs when
a card is presented to the reader, the reader may be installed incorrectly. A short fl ash indicates that the reader
is correctly installed, but the card is the wrong type or that the reader was incorrectly programmed.
External Power Supply
Electromagnetic
LOCK 2
D1NC
COM
D1NO
D2NC
COM
D2NO
Z1
COM
Z2
Z3
COM
Z4
GALEO
WIEGAND
KEYPAD 2
The 2-Door expansion module (CA-A470-A ), does not support zone doubling.
NC INPUT
CONNECTION
JUMPER SETTINGS
1
BATTERY CHARGING
Charging the battery at 350mA (jumper ON) takes longer,
but consumes less power. Charging the battery at 700mA
(jumper OFF) takes less time, but consumes more power.
2
HIGH/LOW BIAS
Place the A+ and B- jumpers on LOW only if the 2-Door
Expansion Module is at the beginning (Start Point) of the E-bus
Network. Otherwise, place the A+ and B- jumpers on HIGH
3
EOL
Place the EOL jumper ON if the 2-Door Expansion Module is
at the Start Point or at the End Point of the E-bus Network.
Otherwise, place the EOL jumper OFF.
Figure 6: Connection drawing of the CA-A470-A
Always consult the
12 - 24VDC
regulatory agency in your
-
area for existing regulations
+
regarding doors designated
as emergency exits.
Pull
Station
-
+
EMERGENCY
PULL
DOWN
CA-A470-A
2-Door Expansion Module
LOCK#1
1
STATUS
JP120
LOCK#2
350mA/700mA
4
5
READER#2
BACKUP
DATA
2
1
0
0
NO CARD
0
1
2 CARDS
1
0
ALL CARDS
1
1
UNLOCK DOOR
KEYPAD 2
Buzzer wire
to OUT6
ATZ 2R CONNECTION
Input 1
1KΩ
OR
Transformer
GEL Type Battery
TR16/40
12V - 7 Ah
CDV I
16VAC-40VA
+
AC OK
AUX OK
COMM
CHECK BATT
BATT TRBL
SWITCH
SW1
ADD 1
SW2
ADD 2
SW3
L1Energize
2
L2Energize
SW4
SW5
BACKUP1
SW6
BACKUP2
LOW HIGH
SW7
PULSE 5&6
SW8
N/D
READER#1
DATA
EOL
TX RX
E-BUS
KEYPAD 1
Buzzer wire
to OUT5
READER 1
ATZ 3R CONNECTION
Input 1
1KΩ
OR
EOL
1KΩ
DIP SWITCH SETTINGS
ADD1 and ADD2 determine the 2-Door
4
Expansion Module's address, regardless of the
order that they are connected to the controller.
1
1
OFF
2
ON
3
OFF
Door Strike LOCK 1
12VDC
AC
AC
BAT+
BAT-
V+
V+
V-
V-
To Reader 1
OUT5
OUT6
To GALEO
WIEGAND Keypad 2
E-BUS :
A+
B-
To CT-V900-A or
B-
A+
other expansion
GND
TMP
modules
3
TMP
Connect to tamper
switch (N.C.)
Reader and keypad wiring
may differ from the
diagram. Please consult
your dealer for details.
2
3
4
5
6
7
OFF
BACKUP 1 & 2
5
OFF
determine what the
ON
CA-A470-A will do in
stand-alone mode
www.cdvi.com
www.cdvigroup.com
ON
OFF
8
5