01. Press "Main menu"button
02. Press the "Parameter setting"button
03. Create house (See "Create house"section, p 6)
04. Radio pairing (See "pairing radiators"section, p 6)
05. To delete a device
• Press "Delete a device"button
• Press "heating"button
• Use the arrows to scroll through the list of paired devices.
• Select the device to be deleted
- Note: To make sure that the right device is deleted, identify it first (See below)
- Note: If the first device in a room is deleted, all devices in that room
will be deleted.
• Press "Green check"button to confirm
06. To delete all devices
• Press "Delete all devices"button
• Press "Green check"button to confirm
• Press "Red cross"to decline
07. Identify a device and edit some device information; such as name, power,
surface temperature limitations and sequential mode.
• Press "Identify a device"button
• Press the "Radio button"
• Make the device send a radio message
- (On Yali, press OK and wait for the backlight to go off)
• Make a note of the ID-number that is displayed on 3rd line of the screen >>
• To be sure it is right, send a second radio message from the device and compare
the ID-number (it could happen that another device coincidently sends a
message at the same time, therefor it is good to repeat this operation).
• If you want to edit device information/settings, press the button with a Red dot
(long Press):
- Device name,
- Power,
- Set front panel max surface temperature level.
> Press "Heating rate maximum level" rate.
> Select P1, P2 or P3. NOTE: the first paired radiator must have the same
or higher value than the rest of the radiators in the room, otherwise the energy
calculation will be wrong.
> Press "Green check"button to confirm.
- For double radiator, change to sequential control.
> Press "Sequential control"button
> Select "No"(default setting) if the radiator's front and back panel should be
evenly heated.