Assembly
1. Attach the carrying strap [6] to the tank. (Fig. 2)
2. Insert the riser pipe [8] of the hose line [3] into the tank opening and secure the hose
line [3] with the cap nut. (Fig. 4a)
+
Make sure that the riser pipe [8] in the tank points upwards in the direction of the
pump opening.
3. Screw the shut-off-valve [4] on the hose connection [3a]. (Fig. 4a)
+
Make sure that the O-ring [3b] is positioned properly in the groove of the shut-off-
valve.
3. If required, screw the extension wand [25] between shut-off-valve [4] and nozzle [14]
(Fig. 4b)
Checks
Visual inspection:
gauge [7], shut-off valve [4], extension wand [25] and nozzle [14] are undamaged.
+
Pay special attention to the connections between the tank – hose line and hose line
– shut-off valve and to the condition of the pump threading.
No leaks:
Pump up the empty device to 2 bar. (Fig. 10)
► The pressure must not decrease more than 0.5 bar within 30 minutes.
Pull up the piston pressure gauge [7]. (Fig. 3)
Function:
► The pressure must dissipate.
+
Using the wheel lock [27] the lever on the shut-off valve [4] can be locked and unlo-
cked. Unintentional spraying is prevented after locking (Fig. 12a)
► If required, reset the wheel lock [27] and activate the shut-off valve [4].
(Fig. 12a and 12b)
► The shut-off valve must open and close.
Have damaged parts or parts that do not work properly repaired immediately by
our customer service department or by service partners authorized by us.
Making preparations
Observe the instructions in the section entitled „Safety".
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank
1. Pull up the red button on the piston pressure gauge [7] until all excess pressure is
released from the tank (Fig. 3)
2. Press the piston rod with handle [9] down and turn into the lock.
The piston rod with handle is locked. (Fig. 5)
3. Unscrew the pump [2] from the tank. (Fig. 6)
4. Add the liquid to the tank [1]. (Fig. 7)
5. Where appropriate, add cleaning agent.
6. Check the filling level with the scale [10] on the tank. (Fig. 7)
7. Screw the pump [2] into the tank. (Fig. 8)
AUS
USA
Check that tank [1], pump [2], hose line [3], piston pressure
14