OBJ_BUCH-844-008.book Page 15 Wednesday, March 16, 2016 4:54 PM
g Outer edges, to be marked left and right via
marking aid 3
h Operating-mode indication
i Grey: Found object outside of the sensor range
j Black: Found object within the sensor range
k Centre line, corresponds with the marking aid 1
l Indication of the allowable drilling depth
m Indication of the object material
n "Live" wire indicator
Technical Data
Universal Detector
Article number
Measuring accuracy to the object
1)
centre a
Accuracy of the indicated allowable
1)
drilling depth b
Minimum distance between two neigh-
1)
bouring objects c
Operating temperature
Storage temperature
Batteries
Rechargeable batteries
Operating time, approx.
– Batteries (alkali-manganese)
– Rechargeable
batteries (2500 mAh)
Degree of protection
Dimensions
Weight according to EPTA-Procedure
01:2014
1) See graphic
c
b
a
2) Depending on size and type of object as well as material
and condition of the base material
In terms of accuracy and scanning depth, the meas-
urement result can be inferior in case of unfavourable
surface quality of the base material.
The measuring tool can be clearly identified with the serial
number 8 on the type plate.
Bosch Power Tools
Assembly
Inserting/Replacing the Batteries
To open the battery lid 4, press the latch 5 in the direction of
the arrow and remove the battery lid. Insert the batteries/re-
chargeable batteries. When inserting, pay attention to the
correct polarity according to the representation on the inside
of the battery compartment.
The battery indicator b in the upper status line on the display
16 indicates the charge condition of the batteries/rechargea-
ble batteries.
Note: Pay attention to the changing battery symbol so that
D-tect 150
the batteries/rechargeable batteries are replaced in time.
3 601 K10 005
Please change batteries
2)
±5 mm
2)
±5 mm
2)
4 cm
possible. Change the batteries/rechargeable batteries.
–10...+50 °C
To remove the batteries/rechargeable batteries, press on the
–20...+70 °C
rear end of a battery as indicated in the figure on the battery
4 x 1.5 V LR06 (AA)
lid ( ). The front end of the battery/rechargeable battery is
4 x 1.2 V HR06 (AA)
released from the battery compartment ( ), so that the bat-
tery/rechargeable battery can easily be removed.
Always replace all batteries/rechargeable batteries at the
5 h
same time. Do not use different brands or types of batter-
ies/rechargeable batteries together.
7 h
Remove the batteries/rechargeable batteries from the
IP 54 (dust and
measuring tool when not using it for longer periods.
splash water
When storing for longer periods, the batteries/rechargea-
protected)
ble batteries can corrode and self-discharge.
22 x 9.7 x 12 cm
Operation
0.65 kg
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. In case of large var-
iations in temperature, allow the measuring tool to ad-
just to the ambient temperature before switching it on.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool and the display in-
dication can be impaired.
Do not attach any stickers or name-plates to the sensor
area 9 on the back of the measuring tool. Especially met-
al name-plates affect the measuring results.
Use or operation of transmitting systems, such as
WLAN, UMTS, radar, transmitter masts or microwaves,
in the close proximity can influence the measuring
function.
The measuring values can be impaired through certain
ambient conditions. These include, e.g. the proximity
of devices that produce strong electric, magnetic or
electromagnetic fields, moisture, metallic building ma-
terials, foil-laminated insulation materials or conduc-
English | 15
When the "Please change
batteries" warning indica-
tion is indicated on the dis-
play 16, the settings are
saved and the measuring tool
switches off automatically.
Measurements are no longer
1 609 92A 27D | (16.3.16)