Important!
All maintenance operation on the
equipment must be carried out by
qualified personnel.
6. Solutions to possible problems
Attention!
It is very dangerous to touch any
electric part that could cause seri-
ous injuries to people. The mainte-
Problem
The burner does not start
The burner starts, the flame
does not ignite, the unit is
blocked
The burner starts, ignites ,
the unit is blocked
The burner starts, but
combustion is not regular
5. Maintenance
Every 12 months the equipment
must be cleaned, however if the
unit is situated in a dusty or dirty
room this operation must be repeat-
ed more than often.
nance of the electric system must
always be carried out by an author-
ized Technical Service or, in any
case, by qualified personnel.
Probable cause
- The plug is not inserted
- Faulty cable
- Room thermostat on low tempera-
tures
- Thermostat cap not inserted correctly
- The safety thermostat has been
activated
- The oil nozzle is obstructed
- Faulty electrodes
- Faulty flame control device
- Not enough oil in the tank
- The oil pump has no pressure
- The gas pipes are not sealed, the
pump sucks air
- The oil pipes are not sealed, the
pump does not suck air
- The pump does not have enough
pressure
- The photocell does not receive light
or is faulty
- The air regulator does not function
correctly
Solution
- Insert the plug
- Check the cable
- Regulate at a higher temperature
- Insert the cap
-Try to eliminate the over heating
- Call your Technical Assistance
Service
- Call your Technical Assistance
Service
- Call your Technical Assistance
Service
- Fill the tank
- Call your Technical Assistance
Service
- Close the pipe fittings
- Close pipe fittings
- Call your Technical Assistance
Service
- Call your Technical Assistance
Service
- Call your Technical Assistance
Service
13