Attention!
The hot air space heaters function
with oil burners. It is necessary that
authorized personnel connects the
equipment to the regular feeding
system by following all instructions
indicated on the leaflet and all safe-
ty rules.
Attention!
The exhaust gas released can be
very dangerous if expelled in a
room with people or animals. For
Important!
Before using the equipment always
check that the electric cables are
not damaged.
The power cord can only be
changed by qualified personnel.
4.1 Start up
The equipment can be used with
and without the room thermostat. If
a room thermostat is used:
a)
take off the thermostat socket
cap
b)
insert the thermostat plug in
the socket
If a room thermostat is not used
you should insert the thermostat
cap in the socket.
12

3. Installment instructions

this reason it is important to con-
nect a pipe and external chimney to
expell the exhaust gas outside.
Attention!
The hot exhaust gas can be dan-
gerous and could start a fire. Do
not use the equipment in premises
that contain explosive materials
inside or any kind of live flame.
When installing the equipment on
building sites or on agricultural land
remember to follow all safety rules

4. How to use the equipment

Connect the cable to the electric
power system.
For all threephase models it is
necessary to have a threephase
400 V socket with neutral and earth
wire.
Connect the equipment to a chim-
ney or to a pipe in order to expell
the exhaust gas outside. Check
that there is a forced draught of at
least 0,1 mbar.
If there is a thermostat adjust it at
the temperature you wish to obtain.
Position the change-over switch on
the
position (for heating). In this
way you start the burner and a few
seconds later, necessary for pre-
heating, the fan starts rotating.
and the regular injury-prevention
legislation.
We also advise you to respect the
following minimum safety distance
from any inflamable element:
on both sides:
above:
air entry side:
air exit side:
These units can be used without a
chimney only in open premises.
Ventilation
Carefully connect the electric cable
of the equipment to the socket.
Position the change-over switch on
position (for ventilation).
4.2 Switching off
Heating
Position the change-over switch on
the"O" position. When the burner
stops, the ventilator goes on oper-
ating to cool the combustion cham-
ber and later stop automatically.
Ventilation
Position the change-over switch on
the "0" position.
0,60 m
2,00 m
0,60 m
2,00 m