Safety Instructions; Work Area Safety - Hilti TE 500 Mode D'emploi

Burineur électropneumatique
Masquer les pouces Voir aussi pour TE 500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Power tool
Weight in accordance with EPTA procedure 01/2003
TE 500
Weight in accordance with EPTA procedure 01/2003
TE 500-AVR
Dimensions (L x W x H)
Single impact energy in accordance with EPTA proced-
ure 05/2009
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Noise and vibration information (measured in accordance with EN 60745‑1):
Typical A‑weighted sound power level for the
TE 500/ TE 500‑AVR
Typical A‑weighted sound pressure level for the
TE 500/ TE 500‑AVR
Uncertainty for the given sound level
Additional information about the TE 500‑AVR in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
Chiseling, a
h, Cheq
Uncertainty (K)
Additional information about the TE 500 in accordance with EN 60745
Triaxial vibration values (vibration vector sum)
Chiseling, a
h, Cheq
Uncertainty (K)
Other information about the power tool
Chuck
Protection class as per EN

5 Safety instructions

5.1 General Power Tool Safety Warnings
a)
WARNING
Read all safety warnings and all instructions. Fail-
ure to follow the warnings and instructions may result
in electric shock, fire and/or serious injury. Save all
warnings and instructions for future reference.
The term "power tool" in the warnings refers to
your mains-operated (corded) power tool or battery-
operated (cordless) power tool.
TE 500 / TE 500‑AVR
5.6 kg
5.7 kg
471 mm x 108 mm x 243 mm
7.5 J
105 dB (A)
94 dB (A)
3 dB (A)
Measured in accordance with EN 60745‑2‑6
10.1 m/s²
1.5 m/s²
Measured in accordance with EN 60745‑2‑6
12.1 m/s²
1.5 m/s²
TE‑Y (SDS‑max)
Protection class II (double insulated) as per EN 60745‑1

5.1.1 Work area safety

a) Keep work area clean and well lit. Cluttered or dark
areas invite accidents.
b) Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
c) Keep children and bystanders away while operat-
ing a power tool. Distractions can cause you to lose
control.
en
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Te 500-avr

Table des Matières