IGNITION / Manual ignition
1.
Turn the power switch to position I and check that the fan starts running cor-
rectly.
2.
Push the gas valve button and push repeatedly (!!) the ignitor (piezoelectric
lighter) until the flame lights up.
3.
As the flame lights up, keep the valve button pushed for 10 seconds approx.
Should the heater stop when the valve button has been released, wait one
minute and repeat the starting operation keeping the valve button pushed
for a longer time.
4.
Contact your supplier should any problem continue.
CAUTION
If ignition is difficult or irregular before repeating the ignition operations make
sure that the fan is not locked and the air inlet and outlet are unobstructed.
SWITCH OFF
To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame
shuts down and then turn the fan switch to position O.
AIR CONDITIONING
1.
The heater can also be used as a ventilator.
2.
In this case remove the gas supply hose and connect the plug of heater to a
suitable electrical supply.
3.
Set the fan switch to position I.
ODOR FADE WARNING
Asphyxiation Hazard
1.
Do not use heater for heating human quarters.
2.
Do not use in unventilated areas.
3.
The flow of combustion and ventilation air must not be obstructed.
4.
Proper ventilation air must be provided to support the combustion air requi-
rements of the heater being used.
5.
Lack of proper ventilation air will lead to improper combustion.
6.
Improper combustion can lead to carbon monoxide poisoning leading to
serious injury or death. Symptom of carbon monoxide poisoning can include
headaches dizziness and difficulty in breathing.
4
25