Personal Protective Equipment (Ppe); Functional Description - Bohle Veribor BO 601.1BL Instructions D'installation

Ventouse à pompe
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Suction lifters must not be subjected to
¡
extreme heat (e.g. open flames, constant
direct sunlight). Temperatures consistently
above approx. 40°C must be avoided at all
costs.
Suction lifters must not be subjected to
¡
extreme cold (e.g. frost). Temperatures
consistently below 0°C must be avoided at
all costs.
We strongly recommend observing the
¡
respective national Manual Handling
Operations Regulations. These regulations do
not only recommend the maximum weights
to be lifted but also the load duration (or
frequency), the adopted body posture and the
conditions under which load handling takes
place.
Check before lifting whether you are
¡
physically capable of lifting the load under
the given circumstances.
Alterations, additions and modifications of
¡
the suction lifter are not permissible. This
applies in particular to the safety devices.
Unauthorised alterations or modifications
will void the supplied EC Declaration of
Conformity.
The use of the suction lifter in environments
¡
subject to explosion hazards (ATEX) is
prohibited.
Operating the device under the influence of
¡
medications which affect perception and
reactions, or under the influence of drugs and
alcohol is forbidden!
Never try to lift cracked or chipped glass.
¡
The operator must be able to view the
¡
vacuum indicator at all times, in order to
assess whether the existing vacuum is still
sufficient. The operator must be able to reach
the priming pump at all times in case the
vacuum must be renewed.
18
Personal Protective
08
Equipment (PPE)
NOTE
Personal protective equipment must be worn for
all work with the suction lifter to minimise health
risks.
WARNING
Different health risks exist when working
with the suction lifter, such as injuries
caused by crushing, entrapment or falling
objects!
Wear safety shoes.
Wear robust protective gloves.
Wear close-fitting, tear-resistant work
clothing.
Functional
09
Description
The pump-activated suction lifter includes a
hand pump (A), a suction pad (D), a venting valve
(B), and a vacuum indicator (C). By engaging the
pump, a vacuum is generated between the suction
pad and the gas-tight surface of the object to
be lifted. A coloured ring or a pressure gauge
serve as vacuum indicator. If sufficient vacuum is
generated, the object can be lifted and carried.
If the vacuum decreases, the user can engage
the pump at all times. The suction lifter can be
released from the object by engaging the venting
valve.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Veribor bo 601.45Veribor bo 601gVeribor bo 601

Table des Matières