Taking Out Of Operation; Disposal; Technical Data; Maintenance - HellermannTyton Relifix Série Notice De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
7 Close the shell until the locking mechanism engages.
Closing the shell.
A small amount of gel must emerge around the cable sheath
while closing the shell to be sure that the joint is perfect
protected against dirt and moisture.
8 Secure the shell with cable ties against accidental
opening.
Securing the shell with cable ties.
; The product has been successfully installed.

6 Maintenance

The product requires no maintenance.

7 Taking out of operation

When installed and used for its intended purpose, the
product will perform continuously without issues.

8 Disposal

After termination of use, the purchaser or the operator
must properly dispose of the product including the
accessories.
This product was manufactured according to the current
environmental protection standards. The materials can be
separated and recycled.
f Observe the national regulations for the disposal of
recyclable materials.
f Do not dispose of the product with domestic waste.
f Take the product to a local collection point or recycling
centre.
f If necessary, contact your local environmental office.

9 Technical data

Characteristics
Insulating properties
Ageing resistance
UV resistance
Weather resistance
Shelf life
Operating temperature
Scope of application
Relifix V 31 .5
Length
Width
Height
Cable diameter
Conductor cross-section
Installation Instructions • Relifix • 11-2016
Maintenance
0.6/1 kV
Yes
Yes
Yes
Unlimited
-20 °C to 90 °C
Interior room, outside, in
water, in the ground and in
installation ducts
86 mm
47 mm
27 mm
9 mm - 16 mm
min.
3 x 0.5 mm²
max.
3 x 2.5 mm²
21