3.1 GENERAL
CURRENT RANGE
OUTPUT VOLTAGE
WORKING VOLTAGE
MAXIMUM ALTITUDE
OPERATING TEMPERATURE
STORAGE TEMPERATURE
TYPE OF SENSING
TEMPERATURE COEFFICIENT : 0.2 x (Spec Acc'y) / °C < 18°C or > 28°C
MAXIMUM OUTPUT IMPEDANCE : 45Ω
MAXIMUM JAW OPENING
MAXIMUM CONDUCTOR SIZE
SIZE
WEIGHT
3.2 ELECTRICAL SPECIFICATIONS
Range
300A
Frequency Response : 50-60Hz
AC97
: 0.1A to 300A AC rms
: 1mV AC per 0.1A AC
: 600V CAT II per IEC 1010-1
: 2000m
: 0°C to 50°C with relative humidity < 80%
: -20°C to 60°C
: induction coil sensing for AC current
: 30mm
: 29mm
: 80 x 156 x 35mm
: 220g
Measure
3 Amp
30 Amp
300 Amp
Output
0.030V
0.300V
3.000V
4
Accuracy
< 50A
± 3.0% ± 10
≥ 50A
± 2.0% ± 5