Checking the vertical line:
Position the device about 5 m from a wall. Fix a plumb bob with a line of
2.5 m length on the wall, making sure that the bob can swing freely. Switch
on the device and align the vertical laser to the plumb line. The precision
is within the specified tolerance if the deviation between the laser line and
the plumb line is not greater than ± 0.75 mm.
Checking the horizontal line:
Position the device about 5 m from a wall and
switch on the cross laser. Mark point B on the wall.
Turn the laser cross approx. 2.5 m to the right and
mark point C. Check whether the horizontal line
from point C is level with point B to within ± 0.75 mm. Repeat the process
by turning the laser to the left.
!
Regularly check the adjustment before use, after transport and after
extended periods of storage.
Technical data
Self-levelling range
Precision
Laser wavelength linelaser (green)
Laser wavelength plumb laser (red)
Laser class
Power supply
Battery operating time (all lasers on)
Battery recharging time
Operating conditions
Storage conditions
Weight (incl. rechargeable battery)
Dimensions (W x H x D)
(Subject to technical alterations. 18W21)
PowerCross-Laser 5G
± 2°
± 0.15 mm / m
515 nm
650 nm
2 / ≤ 1 mW
Lithium-ion rechargeable battery
approx. 4 h
approx. 4 h
0...50°C, max. humidity 80% rH,
no condensation, max. working
altitude 4000 m above sea level
-10...70°C, max. humidity 80% rH
1.4 kg
120 x 120 x 200 mm
2,5 m