It is important to keep the door closed when flames are visible in the fire chamber to avoid smoke nuisances in the
room.
1. Turn the air wheel to the maximum.
2. To minimize the underpressure, the door should be ajar for about one minute before you open it
completely.
3. Open the door slowly.
4. Place two pieces of firewood in the combustion chamber, each of a length of 260 mm and of a total of
approx. 1.4 kg, parallel to the glass and approx. 1 to 2 cm apart. (The test results have been achieved
by positioning the pieces of firewood alongside and behind each other). The stoking interval is approx.
48 minutes.
5. Close the door.
6. Turn down the air supply when the fire has caught the wood, to obtain steady and calm flames.
(The test results at 12 Pa have been achieved by a start-up setting of fully open for 2:00 minutes to
the first click from the right. After 3:00 minutes, the setting is adjusted to between 1
from the right.)
Emptying the ash pan
Open the door and remove the ash pan from a cold stove. Use a closed steel container to store the ash and/or transport it
and discard it in a secure manner. Note: embers may be hidden in the ash for several days.
5. Maintenance
Sealing bands and vermiculite plates are wearing parts and should be replaced as needed. How often depends of the use
of the stove - some stove owners have to change the parts every year whereas others replace them every two or three
years. Sealing bands should be replaced when flat and the front door is no longer tight. New sealing bands with glue may
be ordered from your wood-burning stove dealer.
The vermiculite plates should be replaced when they appear worn or have deep scratches revealing the fire chamber steel.
Worn vermiculite plates should be replaced in time as they will otherwise loose their heat reflection and insulation
properties. Movable and mechanical parts should be greased with a heat-resistant lubricant at least every year (locking
mechanism, hinges, etc.)
The stove and the chimney should be checked regularly by a qualified professional to ensure the optimal function of the
stove. It is illegal to make unauthorized changes to wood-burning stoves and doing so will void the warranty and the test
results.
Renewal of the sealing band at the door
1. Remove the sealing band from the inner frame and clean the band mark (it is not necessary to remove
the door from the stove).
2. Add a band of heat-resistant glue on the band mark.
3. Push new sealing band down into the mark.
4. Close the door and let the glue harden for about 24 hours, before you open the door again. If you do
not let the glue harden sufficiently before you open the door, the band may fall out.
Renewal of the sealing band at the Glass (Cosmo, Cubic, Mido, Cozy Classic)
1. Dismount the screws on the door.
2. Lift off the glass.
3. Remove the old sealing band from the glass.
4. Add new sealing band to the glass.
Renewal of the sealing band at the Glass (Cozy Modern)
1. Dismount the top glass list
2. Lift off the glass.
3. Remove the old sealing band from the glass.
4. Add new sealing band to the glass.
Jydepejsen A/S – September 2019
st
nd
and 2
click