6. Combustion issues.

Combustion issues may be caused by non-optimal combustion conditions.
Follow the instructions below to resolve such issues:
Issue
Explanation
No up-draft
-
The flue gas damper in the smoke pipe is closed.
-
Cleaning door in chimney is defective or missing.
-
A bird's nest or similar is blocking the chimney.
-
Smoke pipe sooting or soot accumulation on top of the
-
baffle plate.
The chimney is too small.
-
Incorrectly fitted baffle plate.
-
Negative pressure in the home.
Too much up-
-
Incorrectly fitted baffle plate.
draft
-
If you are using kiln dried wood, less air supply is
required than for normal wood.
-
DuplicAir® is permanently fully open.
-
The door sealing bands are worn and flat.
-
The chimney is too large.
The glass
-
Too much water in the wood.
windows blacken
-
Air supply
White glass
-
Insufficient combustion (temperature in fire chamber is
too low.)
-
Incorrect wood firing (use of cull, painted wood,
impregnated wood, plastic laminate, plywood, etc.)
Smoke fills the
-
Pressure equalization occurs in the fire chamber.
room when the
door is opened
-
The chimney and the wood-burning stove are not
cooperating.
-
The door is opened with a fire in the fire chamber.
White smoke
-
The combustion temperature is too low.
-
The wood is too damp and contains water vapor.
Black or greyish
-
Incomplete combustion
smoke
not sufficiently open.
Jydepejsen A/S – September 2019
Correction
-
Open the flue gas damper.
-
Contact your chimney sweep / wood-burning
stove dealer for further instructions or clean
the smoke pipe and fire chamber.
-
Check the baffle plate - please refer to the
operating manual.
-
Negative pressure may occur in well-
insulated buildings - increase the air flow to
the room.
-
Check the baffle plate - please refer to the
operating manual.
-
Reduce the supply of air.
-
Check the sealing bands. Worn sealing
bands should be replaced as described in
the operating manual.
-
Contact your chimney sweep / wood-burning
stove dealer for further guidance.
-
Use dry wood with max 20% humidity only.
-
Open
DuplicAir® to feed more air to the
combustion process.
-
Follow the instructions for correct firing as
described in this manual.
-
Make sure you use clean and dry wood in
your stove.
-
Open the air supply completely for about
1 minute before opening the door - avoid
opening the door too quickly
-
Check the height of the chimney as this may
be insufficient to provide the minimum up-
draft required for this stove.
-
Never open the door when you see flames,
only embers.
-
Increase the air supply.
-
Make sure you always use clean and dry
wood in your stove.
-
Increase the air supply.
.

Publicité