thickness of 19mm (3/4"). Do NOT screw directly onto the hull, it must be mounted to
a bulkhead or on an additional board.
7. PARTS LIST
1 x Orca Pump
8. OPTIONAL EXTRAS
BE9003 / BE9006 - Electric Field Sensor Switch (Available seperately)
9. INSTALLATION
WARNING: Please note that incorrect installation may invalidate the warranty.
Preparation - Always disconnect power sources before installing.
9.1 Location
•
Position pump in the lowest accessible
part of the bilge. On sailboats, location
should be centred over keel (Fig 1).
•
Do not mount the pump directly onto
the hull. The base strainer must be
mounted to a bulkhead or an additional
board at least 19mm (3/4") thick.
9.2 Mounting Instructions
Before drilling, ensure that the mounted pump will be correctly positioned with pump nozzle pointing
towards thru-hull connector.
To remove pump body, place hand over body, depress locking tabs and lift body from strainer base.
Note: Motor will be removed with body (see figure 2 and 3).
For Orca 500, 950, 1300 and 2000
•
Use base as template to mark 3 mounting holes for Orca in
mounting pad.
•
Remove base. Drill three 1/8" (3mm) pilot holes for Orca at
marked locations.
•
Replace base. Attach with #8 stainless steel fasteners
(supplied).
•
Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figure 2
and 3).
For Orca 3000
•
Use base as template to mark 4 mounting holes for Orca
3000 in mounting pad.
•
Remove base. Drill four 1/8" (3mm) pilot holes for Orca
3000 at marked locations.
•
Replace base. Attach with #8 stainless steel fasteners
(supplied).
•
Re-attach pump body to base. Insert body into strainer
base, until base tabs snap into holes in body (see figure 3).
9.3 Plumbing
IMPORTANT: To prevent airlock, hose must rise continually upward to the thru-hull connector with
no dips or sharp bends. Hose support clips should be used at regular intervals where necessary.
•
Orientate the pump outlet for a direct path to the hull connector ensuring an
unobstructed hose path.
•
Secure all connections with hose clamps.
•
If no thru-hull connector exists, install at 12" (305mm) minimum height above water
line. Apply marine sealant around thru-hull flanges on interior and exterior of hull.
1 x Screw Kit
Figure 1 -
Mounting Location
Hose must rise upwards
with NO DIPS
Suitable Mounting Pad
Skin Fittings
Outlet 12"
(305mm)
minimum
above
water line
Press
both
locking
tabs to
release
cover
Figure 2 - Release Cover
Orca 500, 950 and 1300
Press both
locking tabs
to release
cover