2.4.7 Setting the alarms
2 alarms can be set for each tank.
Low alarm, an alarm when the level in the
tank is lower than the value set for Low
level.
High alarm, an alarm when the level in the
tank is higher than the value set for High
level.
See the summary below.
Summary of alarm settings
Low alarm
- Off
- On
- On output 1
- On output 2
- On output 3
- On output 4
the option set for low alarm is carried out when the level in the tank
Low level
has dropped to below the set low level
High alarm
- Off
- On
- On output 1
- On output 2
- On output 3
- On output 4
the option set for high alarm is carried out when the level in the tank
High level
has risen to above the set high level
34
090430.01
Multiple alarms -high/low or on different
tanks- can be coupled to the same alarm
output.
If warning lights or buzzers are connected
to the alarm outputs, these can be set off
by an alarm.
The low alarm is switched off.
The low alarm is switched on.
The low alarm is switched on and coupled to
alarm output 1, 2, 3 or 4 respectively.
The high alarm is switched of.
The high alarm is switched on.
The high alarm is switched on and coupled to
alarm output 1, 2, 3 or 4 respectively.
Ultrasonic tank management system