Operating instructions SATA dry jet 2
EN
9.2. Hand-held operation
■ Turn the air flow control [1-3] to the right as far as it will go.
■ Connect the dry jet gun to the compressed air circuit with the connec-
tion nipple [1-5].
■ Turn the air flow control to the left to adjust the required air flow.
■ Hold the dry jet gun in the required working position, making sure it is
aligned correctly (see chapter 9.1).
■ To stop blowing, turn the air flow control to the right as far as it will go
and disconnect the dry jet gun from the compressed air circuit.
9.3. Stand version
Notice!
These operating instructions describe operations with the SATA dry jet 2
stand with height-adjustable holder and 2 dry jet guns (Art. No. 223008).
■ Set the stand up in the correct position and alignment [4-4], [4-9].
■ Connect the stand to the compressed air circuit with the connection
nipple [4-3].
■ Turn the air flow control of the dry jet guns to the right as far as it will
go.
■ Connect the dry jet guns [4-1], [4-8] to the quick couplings [4-2], [4-7]
and align them correctly.
■ Turn the air flow control of the dry jet guns to the left to adjust the
required air flow.
■ To stop blowing, turn the air flow control of the dry jet guns to the right
as far as it will go, then take the dry jet guns off the stand or disconnect
the stand from the compressed air circuit.
10. Maintenance and Care
Risk of injuries from components coming loose
Components may come loose unexpectedly when performing mainte-
nance to the dry jet gun while this is still connected to the compressed
air circuit.
→ Always disconnect the dry jet gun from the compressed air circuit
before performing any maintenance work.
Spare parts are available for carrying out repairs (see chapter 13).
66
Warning!