10. RDNet NETWORK LINK CONNECTOR ("Data Out")
Compatible with network cables with etherCON/RJ45 connectors. Used to link the remote control network to
other system modules in a daisy-chain configuration.
11. CONTROL LEDS
LEDs related to the network (RDNet) operating status. In particular:
•
"Link" illuminates to indicate that the RDNet network is active and has recognised the device
•
"Active" flashes to indicate the presence of data traffic
•
"Remote Preset Active" signals that all the local controls on the amplifier panel are bypassed
by the RDNet remote control
12. USB DATA SERVICE
Using this standard type B USB port, you can update the product's firmware using a PC and USB BURNER
MANAGER. For further information, refer to the website http://www.dbtechnologies.com in the "DOWNLOADS"
section and the chapter UPDATING THE FIRMWARE.
POWER SUPPLY SECTION
13. "MAINS INPUT" POWER SUPPLY CONNECTOR
Compatible with powerCON TRUE1® connectors, the power
supply is equipped with an auto-range function. Once
the appropriate voltage range has been determined and,
if necessary, the fuse changed accordingly, this function
automatically detects whether the voltage is in the range
[100-120V~] or [220-240V~].
14. "MAINS LINK" POWER SUPPLY LINK
Compatible with powerCON TRUE1® connectors, allows
linking of the mains power supply. This output is connected
in parallel with the power supply input (13).
To find out how many modules can be connected in a
linked system, refer to the
section.
15. MAINS FUSE
Mains fuse holder.
•
The subwoofer is supplied equipped with a fuse suitable for operation with a power
supply in the range 220-240 Vac. If it is necessary to operate the subwoofer with a power
supply in the range 100-120 Vac:
1. Disconnect all connections, including the power supply.
2. Wait for 5 minutes.
3. Replace the fuse with the one supplied in the package for the range 100-120 Vac.
4. Only use the power cable provided.
•
The USB SERVICE DATA connection is to be used exclusively for updating the product's
firmware; do not connect any other USB device to the unit to avoid the risk of damage
and malfunction.
•
Do not use the monitor for a prolonged period with the limiter LED steadily lit or
flashing as this indicates operation under stress with excessive distortion.
VIO S115
30
TECHNICAL SPECIFICATIONS
English
Cod. 420120357 REV. 1.0