Sharp MD-MT90H Mode D'emploi page 116

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Recording from a Microphone (continued)
„ Sound-actuated recording (Mic Synchro-
nised recording)
1
Press the REC button.
2
Press the
ing level.
3
Press the ENTER/SYNC button to select the re-
cording sensitivity.
MIC SYNC H :
MIC SYNC L :
4
When a sound, such as person speaking, is
picked up by the microphone, recording will be-
gin automatically.
E-21
ENGLISH
or
button to adjust the record-
Recording starts when the unit
detects
24 dB or more (The unit
-- -
can start recording from quiet
sounds).
Recording starts when the unit
detects
12 dB or more.
- --
About pause function
The unit automatically pauses when the microphone
does not pick up any sound for 3 seconds or more.
(Pause function does not work for approximately 10 sec-
onds after a recording starts.) When the microphone
picks up sound again, recording starts automatically.
Notes:
z Whilst making a mic recording, do not connect any-
thing to the OPTICAL/LINE IN socket on the portable
MD.
z To use a microphone, be sure it is a plug-in-power
type microphone.
- When a plug-in-power type microphone is plugged in,
the portable MD will provide power for the micro-
phone's operation.
- If a different type of microphone is plugged in, it may not
operate properly or it may cause the unit to malfunction.
z Insert the plug firmly. If you don't, the recording will not
be made properly.
z Use a microphone with a 3.5 mm (1/8") diameter stereo
mini plug.
z If the unit starts recording too often from low unwanted
noises, set the microphone input to "MIC SYNC L".
z Recording sensitivity can be changed whilst recording.

Publicité

Table des Matières
loading

Table des Matières