Wiring (Figure 5.)
1.
Pull service wires through mounting arm and into
housing approximately 5" .
a.
2.
Three-terminal block (2-wire service): Connect line
●
service lead to terminal that is connected to black
factory-installed wire. Connect neutral service wire
to terminal that is connected to white
factory-installed wire.
b.
Three-terminal block (3-wire service, 2 lines, 1
●
ground): Connect 1 line service lead to terminal that
is connected to black factory-installed wire. Connect
other line service lead to terminal that is connected
to white factory-installed wire. Connect ground
service lead to terminal that is connected to green
factory-installed wire.
c.
Three-terminal block (3-wire service, 1 line, 1 neutral,
●
1 ground): Connect line service lead to terminal that
is connected to black factory-installed wire. Connect
neutral service wire to terminal that is connected to
white factory-installed wire. Connect ground service
wire to terminal that is connected to green
factory-installed wire.
d.
No terminal block (3-wire service, 2 lines, 1 ground):
●
Connect 1 line service lead to black factory-installed
wire. Connect other line service lead to white
factory-installed wire. Connect ground service lead to
green factory-installed wire.
e.
No terminal block (3-wire service, 1 line, 1 neutral,
●
1 ground): Connect line service lead to black
factory-installed wire. Connect neutral service lead to
white factory-installed wire. Connect ground service
lead to green factory-installed wire.
N
ote:
Terminals are numbered at the wire entrance of
the terminal block.
3.
Ensure all wiring is secure and reconnect the quick
disconnects.
4.
If removed, return access door to hinge and swing the
access door into closed position and secure latch by
rotating 1/4 turn.
Arm Installation (Optional)
Mast Arm: Square Pole (Figure 6.) and Round Pole
(Figure 7.)
1.
Insert nut plate into pole and align insert holes with the
mounting holes in the pole.
2.
Insert threaded rods through the top and bottom holes.
Screw into nut plate.
Installation Instructions - Archeon
Install Direction
Figure 4.
Three or
Four-Position
Terminal
Block
Figure 5.
Arm
Figure 6.
COOPER LIGHTING SOLUTIONS
Quick Disconnects
in Rear of Door
(Not Shown)
Neutral
Lead
Hot Lead
Ground Lead
Cover Plate
(2) Threaded Rods
(2) Nuts
(2) Washers
Electrical Wires
Square Pole
IB521005EN
Installation instructions
Small
TM
Nut
Plate
3