Press the SET button once to enter the circulation pump speed setting menu:
The pump speed is set to 100% by default .
Wait for the pump to start and the re-reading of the flow in the second line of the screen is stable .
7.3.2 - CHECKS
With the pump running, perform the following checks:
•
Hydraulic circuit bleed
•
Hydraulic pressure between 1.5 and 2.0 bar
•
Hydraulic circuit water flow
7.3.3 - WATER FLOW REGULATION PROCEDURE
The heat pump is equipped with a variable speed pump adjustable by a control system .
From the previous menu (pump speed setting) you can set pump speed during normal operation and re-read
the water flow at the set speed .
To change the pump speed, press s or t buttons until the desired flow rate is reached . After any change, wait
a few seconds for re-reading the flow to be stable .
•
Change the pump speed to obtain, depending on the application, the rated working capacity according to
the following table:
Application
Radiant surface
Fan coil
Low temperature radiators
S P E E D : 1 0 0 %
Q : 1.62
m 3 / h
S P E E D : 8 5 %
Q : 1.3 8
m 3 / h
Indoor unit
Water
outlet t.
Outdoor unit
3
35°C
Flow m
/h
3
45°C
Flow m
/h
3
55°C
Flow m
/h
33
33
AUAH AUBH
AUCH
G50
G65
G80
0 .72
1 .10
1 .33
0 .67
1 .10
1 .33
-
0 .55
0 .64
EG
AUDH
G110
G140
1 .83
2 .34
1 .82
2 .34
0 .88
1 .12