3. Technical
Nominal rated operating voltage:
Operating voltage range:
Maximum overvoltage:
Maximum reverse voltage:
Current consumption
(max values at 23°C):
Maximum operating temperature:
Minimum operating temperature:
IP grade:
Alarm's siren sound pressure level:
Specifications
– Disarm state
– Arm state
– Alarm state
+12 V DC
+8 to +16 V DC
+24 V DC per 1 minute
−18 V DC per 1 minute
< 0.5 mA (+12 V DC)
< 1.0 mA (+12 V DC)
< 300 mA (+12 V DC)
+85°C
−40°C
IP 40 or IPX5
> 111dB in open field (1m)
VSS1
13