Routine Maintenance - TECO Seachill TANK Série Traduction Du Mode D'emploi Original

Masquer les pouces Voir aussi pour Seachill TANK Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
TANK
6
MANTAINANCE
6.1

ROUTINE MAINTENANCE

Filter cleaning should be carried out at least once every month and whenever it's necessary according to the
level of dust in the installation place.
Open the plastic grid from the top (Rif. A6 Fig. 14) and remove the fi lter (Rif. A5 Fig. 14).
Clean out the fi lter by washing it with warm water.
CAUTION: Do not use hard brushes or blunt instruments to avoid damaging the fi lter.
Replace the fi lter (Ref. A5 Fig. 14) and close the plastic grid (Ref. A6 Fig. 14).
7
DIAGNOSTICS, PROBLEMS, CAUSES AND REMEDIES
7.1
Disadvantages, causes and remedies table
Disadvantages
Display
does
not
light up.
Insuffi cient
water
cooling.
On the display ap-
pears the message
"HA2" (overheating).
Insuffi cient
water
heating.
On the display appears
the message "P1".
On the display appears
the message "P2".
On the display ap-
pears the message
"HA".
On the display ap-
pears the message
"LA".
The temperature dis-
played is not the real
one.
WARNING: Before you unplug the device from the pipes it is necessary to tighten the pipes
with the special squeeze-tube clamp (Ref. B5 Fig. 10) to prevent the escape of water from the
aquarium, once reconnected the unit to re-open the clamp.
Make sure that the operator can check from any point he has access that the plug remains disconnected.
12
C H I L L E R L I N E
Causes
No electricity
Insuffi cient water fl ow. Check the proper operation of the pump (not supplied) (Rif.
Aquarium isolation is
not enough.
Outgoing
air
from
the ventilation grid at
room temperature.
Dirty air fi lter.
Ambient temperature
is too high.
Obstructed ventilation
grate.
Broken ventilation system. Contact the TECO S.r.l area retailer.
Insuffi cient water fl ow.
Defective heater.
Damage of the water's
temperature probe.
Damage of the overheat-
ing temperature probe.
High water tempera-
ture.
Low water tempera-
ture.
The water does not
circulate correctly in-
side the hydraulic cir-
cuit.
Long and not insulated pipes. Reduce as much as possible the pipes and insulate them.
Temperature
sensor
not calibrated correctly
Check if the power supply plug is fully inserted into the power
outlet (Rif. A5 Fig. 4).
A1 Fig. 12-13).
Insulate the walls of the aquarium and the pipes to reduce
heat loss.
Lack of gas in the compressor, contact the TECO S.r.l area
retailer.
Clean the air fi lter following the instruction (Chapter 6 Maintenance).
Restore the optimal environmental conditions.
The maximum ambient temperature allowed is 38°C (100°F).
Remove the obstruction from the ventilation grate or place the
chiller in one most suitable environment.
Check the correct operation of the pump (not supplied) (Rif.
A1 Fig. 12-13).
Contact the TECO S.r.l area retailer.
Contact the TECO S.r.l area retailer.
Contact the TECO S.r.l area retailer.
Check the correct operation of the pump (not supplied) (Rif. A1 Fig. 12-13).
Check that there are no crimps in the tubing.
Check that the cooling function is activated.
Check the correct operation of the pump (not supplied) (Rif. A1 Fig. 12-13).
Check that there are no crimps in the tubing.
Check that the heating function is activated (if present).
Check eventually pipes obstructions.
Check the effi ciency of the aquarium's pump (not supplied).
Calibrate the temperature sensor as described in paragraph
5.2.2 Thermostat Settings.
Tab. 7-1
Remedies
EN

Publicité

Table des Matières
loading

Table des Matières