TANK
5.2.1
Information on the display
On:
On:
Flashing light:
Flashing light:
On:
5.2.2
Thermostat settings
Refer to fi gure 15 for buttons detection.
1) To change the temperature of the water:
a. Push the button SET for 3 seconds (Rif. A8), display shows the current value setting and the unit of
measure icon (C or F ref C3) starts to blinking.
b. Modify the parameters using the arrows
c. Push the button SET (Rif. A8) to confi rm the values.
2) To adjust other parameters: hysteresis function (Hy), probe calibration (Ot), ) and to exclude the heater func-
tion (O1):
d. Access to the programming menu by pressing the SET+
icon unit selected starts blinking (C or F ref C3) and appears Hy.
e. Scroll through the parameters using the arrows
f.
Press the SET button (ref A8), the current set value is displayed.
g. Change the value using the arrows
h. Press the SET button (Ref. A8) to confi rm the setting and move to the next parameter.
i.
Press SET +
NOTE: If you do not press any buttons for 30 seconds, all settings are saved and the device is
ready for operation.
Parameter
Preset value
Hy
Ot
o1
rL
5.3
TRANSPORTATION AND STORAGE
The conditioner must be handled carefully in a vertical position using the handles. It is recommended to placed
it on a fl at surface.
5.4
DEMOLITION AND DISPOSAL
The crossed-out wheelie bin label that can be found on your products, indicates that the product may not be
treated as household waste. By ensuring that this product is disposed of correctly, you will help preventing poten-
tial negative consequences for the environment and human health, which could otherwise be caused by inappro-
priate waste handling of these products. For more detailed information about recycling of this product, please
contact your local city offi ce, your household waste disposal or the dealer where you purchased this product.
This information only applies to customers in the European Union, according to Directive 2002/96/EC of EU-
ROPEAN PARLIAMENT and THE COUNCIL OF 27January 2003 on waste electrical and electronic equipment (WEEE) and
legislation transposing and implementing it info the various notional legal systems. For other countries, please contact your local
government to investigate the possibility of recycling your product.
C H I L L E R L I N E
unit in cooling mode (Ref. A9 Fig. 15).
unit in heating mode (Rif. B1 Fig. 15).
unit ready for cooling (Rif. A9 Fig. 15).
unit ready for heating (Rif. B1 Fig. 15).
alarm condition (Rif. A1 Fig. 15).
(Ref. A8 and C2) to exit programming mode.
This parameter sets the hysteresis, that is the
1°C
This parameter adjusts the probe calibration: it allows to
0°C
compensate for the diff erence in the temperature reading
on the display compared to the actual water temperature.
Activation / deactivation of the heating function:
On
- Set "On" to activate the heating function
- Set "OFF" to deactivate the heating function.
xx.x
and
(Rif. C2 and A7) (5 ÷ 35°C / 41 ÷ 95°F).
and
and
(Rif. C2 and A7).
Description
diff erential of the unit.
Firmware version of thermostat.
Read-only parameter.
Tab. 5-2
button for 3 seconds (Ref. A7 and A8). The
(Ref.C2 and A7) until the desired parameter.
EN
Regulation range
0,5 ÷ 10°C
1 ÷ 45°F
-12 ÷ 12°C
-20 ÷ 20°F
On - OFF
-
11