Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Raindance Connect Showerpipe 27164000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
6

Safety Notes

Gloves should be worn during installation to prevent crushing and cutting
6
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
6
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
6
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such as your
6
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
6
installed.
The shower system may only be used for bathing, hygienic and body cleansing
6
purposes.

Installation Instructions

• Prior to installation, inspect the product for transport damages.After it has been
installed, no transport or surface damage will be honoured. The fitting must be
installed, flushed and tested after the valid norms!
• Where the contractor mounts the product, he should ensure that the entire area
of the wall to which the mounting plate is to be fitted, is flat (no projecting joints
or tiles sticking out), that the structure of the wall is suitable for the installation
of the product and has no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall constructions the manufacturer's
indications of the dowel manufacturer have to be taken into account.
• If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
• The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• The shower may only be connected following (downstream from) a shut-off valve
of the sanitary fitting.
• The installation dimensions stated in this installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case you will have to attend to the minimum height of
2190 mm from shower tray floor, and alter all the required measurements as
necessary.
4
English
Assembly see page 34
corner fitting set see page 36

Technical Data

Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
anti-pollution function
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 38)
Spare parts (see page 40)
Dimensions (see page 31)
Flow diagram (see page 31)
overhead shower
Hand shower
Operation (see page 38)
Cleaning (see page 39) and enclosed brochure
Test certificate (see page 40)
max. 0,6 MPa
0,1 – 0,4 MPa
max. 60 °C
max.70°C / 4 min

Publicité

Table des Matières
loading

Table des Matières