a) Current clamp
1 Clamp
2 Setting wheel
3 Light button
4 LCD display
5 Battery compartment (back)
b) LCD display
Symbols
No.
Symbol
A
A
B
--
C
MAXH
D
E
F
AC
Resolution
Measurement range
2.000 A~
20.00 A~
200.0 A~
Specified accuracy ± (% of the reading + display errors in counts). The accuracy is maintained
for one year at a temperature of +23 °C (± 5 °C) at a relative humidity of ≤75 %, non-condensing.
22
Control display/display
Control display - current
Measurement value
Control display - maximum value
Control display - hold
Control display - battery
Control display - alternating current
Resolution
1 mA
10 mA
100 mA
6 Hole for a strap
7 MAXH button
8 HOLD button
9 Opening lever
Accuracy
± (4 % + 30)
± (3 % + 10)
± (2.5 % + 5)