POWER CABLE AND DROP
The power supply cable must be suitable to immersion.The diagram below show the maximum possible length
of the cable (unit of measure m), considering the cross section of the conductors.
Those diagrams are true for a maximum voltage drop of 3% with a working temperature of 35°C.
For different voltages consider : diagram length xVolt pwr supply/380.
MOT.
Hp
Mod.
Cable section mm²
(V380-
415/50)
4x1.5 4x2.5
6MFE 55
5.5
6MFE 75
7.5
6MFE 100
10
6MFE 125 12.5
6MFE 150
15
6MFE 175 17.5
6MFE 200
20
6MFE 250
25
6MFE 300
30
6MFE 400
40
MOT.
Hp
Mod.
Cable section mm²
(V380/60)
4x1.5 4x2.5
6MFE 55
5.5
6MFE 75
7.5
6MFE 100
10
6MFE 125 12.5
6MFE 150
15
6MFE 175 17.5
6MFE 200
20
6MFE 250
25
6MFE 300
30
6MFE 400
40
Splicing the drop cable to the motor cable must be carried out through suitable resin filled kit, following the
producer's instructions and don't forget to join the core cable with the same colour (black-blue-red).
INSTALLATION
The normal working position is vertical.
The drop cable must be secured to the riser pipe at intervals no longer than 2.5m.
The motor must be positioned at a distance of 1 m from the well bottom to avoid the accumulation of sand
or mud.
4x4
4x6
110
160
250
68
108
161
53
84
126
44
70
104
59
87
70
65
4x4
4x6
110
160
250
68
108
161
53
84
126
44
70
104
59
87
70
65
4x10
4x16
4x25
400
265
415
207
325
171
267
413
144
223
347
130
200
316
107
167
258
87
136
210
75
117
181
110
170
4x10
4x16
4x25
400
265
415
207
325
171
267
413
144
223
347
130
200
316
107
167
258
87
136
210
75
117
181
110
170
4x35
380
350
295
246
235
4x35
380
350
295
246
235