13. Adjustments

Various adjustments can be made using the free software (FAR Order
No. 4897 00 00).
The shower remains locked for 2 min after each shower procedure. This time of
occupancy can not be changed.
Adjustable Parameters
• Payment time:
– Time during which the coins or chips must be inserted into the counter. The
shower is enabled after this time has elapsed.
Additional coins are not counted.
– Adjustable range: 1-30 sec
– Factory setting: 10 sec
• Delivery unit:
– Duration of media deliver per paid unit. Up to 30 coins can be inserted.
– Adjustable range: 1-510 sec
– Factory setting: 3 min
• Expiration time:
– Time until the credit expires when not used. The shower is enabled for
payment.
– Adjustable range: 1-30 min
– Factory setting: 5 min

14. Maintenance and Servicing

• The coin-activated switch does not require special maintenance.
• Use a moist microfibre cloth to remove any external soiling on the housing.

15. Fault Correction

Fault
Water does not flow
Water flows conti-
nuously
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Cause
– Voltage supply interrupted
– Coin-activated switch faulty
– Coin-activated switch faulty
- 8 -
Remedy
➯ Restore it
➯ Replace
➯ Replace