General description
This capacitive Sensor KXC-... from the Extreme-Range Series of RECHNER Sensors is based on the
three-electrode measuring principle. With this measuring principle, one electrode is removed to the outside.
The protective conductor-potential PE – this means the machine and system potential – is integrated as
a measurement electrode. As a result, it is possible to achieve larger sensing distances.
Technical data
Operating distance S
n
Operating distance min / max adjustable
Output function
Operating voltage (U
B
Output current max. (I
Permitted ambient temperature
LED-display
Degree of protection IEC 60529
Connection cable
Housing material
For further technical data view specification sheet
Ø9
100
)
)
e
120
45
120 mm
20...200 mm
Antivalent (NO + NC)
18...36 V DC
2 x 0...250 mA
-25...+55 °C
Green / yellow
2 m, PVC, 4 x 0.34 mm²
30
IP 67
PBT
9