output is enabled and that is to say when the thermostat calls for heat (heating)
using the NO connector of the relay.
In Figure 6 is shown how to connect the receiver to the "ambient thermostat"
of a boiler. Follow this diagram when you need to replace the wired thermostat
connected to a boiler with a wireless thermostat or chronostat.

CONFIGURING THE SYSTEM

To be able to install several thermostats in the same area and to be able to use
the multichannel systems, every thermostat is equipped with its own address
code. Thermostats with different addresses can work at the same time without
interfering each other and therefore controlling different areas.
In order to set up and store in the receiver the address of the thermostat from
which want to receive the signals, it is necessary to perform the self-learning
procedure described below.
Self-learning procedure
- Make sure that the plastic enclosure of the receiver is closed before powering
up the circuit, as all the internal parts are subject to high voltage 230V~.
- Switch on the receiver: the LED
initialisation phase.
- Switch on a single thermostat or chronostat and set it in the "test" mode
(this means that the transmitter will continuously emit an ON command
followed by an OFF command after three seconds). It is advisable to keep the
transmitter in the same room as the receiver.
- Press the self-learning button for a second by inserting a small screwdriver
1