FilterCart Original
6
7
14
WARNING!
Work safety regulations. Risk of personal injury, fire or explosion.
The unit must not be used in an environment with danger of explosion or for
dust or gases in explosive concentrations.
If the unit has been used for dust applications it must not be used for
welding fumes or grinding dust.
Check that no sparks or other objects that can cause fire are sucked in to the
arm. For welding applications generating a high amount of sparks, a spark
protection (accessory) must be mounted in the hood to reduce the risk of
fire. See figure 8.
The unit must not be used for extracting toxic substances.
The unit must not be used without filter cartridge and casing.

Changing the filter cartridge

The filter cartridge is disposable and is to be thrown-away after use. The life
of the filter cartridge varies greatly depending on how the unit is used, how
much and what type of pollutants are collected.
Regularly monitor the unit's extraction capacity at the hood and change the
filter cartridge when the extraction capacity is too poor. Always check that the
hoses for the extraction arm and the fan inlet are not damaged before it is
decided to change the filter cartridge.
WARNING!
Risk of personal injury.
Use necessary personal safety equipment when replacing the filter cartridges.
Change the filter cartridge as follows (see also Figure 5):
Disconnect the mains connection cable.
1.
Unlock the eccentric locks and remove the filter casing.
2.
Use the plastic bag which comes with the new filter cartridge and pull it
3.
over the used cartridge. Fold the plastic bag under the cartridge.
Handle the used filter cartridge according to the relevant regulations for
4.
the collected substances.
Wipe off the filter cartridge contact surfaces in the unit.
5.
Check that the new filter cartridge is not damaged. Then fit it on the unit.
6.
Refit the filter casing. Make sure the eccentric locks tighten the filter
7.
casing properly.
A: Increasing the locking power.
B: Decreasing the locking power.

Changing the HEPA filter (accessory)

If the unit has been supplied with a HEPA filter, the filter is to be changed
when the main filter cartridge is changed.
WARNING!
Risk of personal injury.
Use necessary personal safety equipment when changing the HEPA filter.