Voltage *
Phase *
Frequency *
Spot light
Transformer
Weight:
Temperature, max. ambient temp.
Temperature, max. airflow temp.
Noise level
Material recycling
* See type label.
See wiring diagram, Figure 2, for electrical details.
E1: 20 W, 24 V.
F1: Start/stop overload protector.
F2: 1 AT, 5 x 20 mm.
T1: Transformer.
M1: 0.75 kW.
4
Hood mounting instruction
The Fume Extractor arm is already fitted. The hood must be fitted according to
the Figure 3, items A–D.
Insert the hood into the swiveling arm, and fasten together.
A.
Adjust the swiveling arm to the correct tension.
B.
Ensure that the swiveling arm has the correct tension and can be easiliy
C.
positioned.
Fasten the blue hose into the hood and secure it using the tightening
D.
ring.
5
Directions for use
The unit is only intended for indoor use and is designed for extraction and
filtration of dust or welding fumes. It must not be used for extraction of fluids.
Figure 4 and the following list illustrates how to use the unit:
Lever for adjusting the damper.
1.
Switch for spotlight.
2.
The hood of the extraction arm is to be positioned as close to the pollution
source as possible. The unit is to be moved from behind according to Figure 4,
item A and with the wheels unlocked. The extraction arm is to be positioned
with the wheels locked according to item B.
FilterCart Original
110/120/2390/240
1 ~
50/60 Hz
20 W, 24 V
24 V secondary
•
71 kg (156 lb) with 2 m arm
•
73 kg (161 lb) with 3 m arm
40 °C (104 °F)
60 °C (140 °F)
73 dB(A) ISO 11203
90 weight-% without filter cartridge
EN