Milwaukee 6276-20 Manuel De L'utilisateur page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SERVICE
• Have your power tool serviced by a qualifi ed
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
SPECIFIC SAFETY RULES
• Hold power tool by insulated gripping surfaces,
when performing an operation where the cutting
accessory may contact hidden wiring or its own
cord. Cutting accessory contacting a live wire may
make exposed metal parts of the power tool live and
could give the operator an electric shock.
• Use clamps or another practical way to secure
and support the workpiece to a stable platform.
Holding the work by hand or against your body
leaves it unstable and may lead to loss of control.
• Keep hands away from all cutting edges and
moving parts.
• Maintain labels and nameplates. These carry
important information. If unreadable or missing,
contact a MILWAUKEE service facility for a free
replacement.
• WARNING Some dust created by power sanding,
sawing, grinding, drilling, and other construction
activities contains chemicals known to cause
cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:
• lead from lead-based paint
• crystalline silica from bricks and cement and other
masonry products, and
•arsenic and chromium from chemically-treated
lumber.
Your risk from these exposures varies, depending
on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well
ventilated area, and work with approved safety
equipment, such as those dust masks that are spe-
cially designed to fi lter out microscopic particles.
SPECIFICATIONS
No Load
Cat.
Volts
Length of
Amps
Strokes Per
No.
AC
Minute
6276-21
120
6.2
500-3000
FUNCTIONAL DESCRIPTION
13
10
12
1
2
7
6
5
3
4
1. Quik-Lok tension lever
2. Transparent blade cover
3. Blade
4. Shoe cover
5. Keyless shoe
6. Orbital action selector lever
7. Tilt angle scale
8. Vacuum manifold
9. Shoe adjustment lever
10. On/Off switch
11. Speed control dial
12. Blower adjustment dial
13. Cutting guide
SYMBOLOGY
Double Insulated
Amperes
Volts
Alternating Current
No Load Revolutions
per Minute (RPM)
Underwriters Laboratories, Inc.
United States and Canada
4
GROUNDING
WARNING
Improperly connecting the
Stroke
grounding wire can result in the risk of elec-
1"
tric shock. Check with a qualifi ed electrician
if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug
provided with the tool. Never remove the
grounding prong from the plug. Do not use
the tool if the cord or plug is damaged. If
11
damaged, have it repaired by a MILWAUKEE
service facility before use. If the plug will not
fi t the outlet, have a proper outlet installed by
a qualifi ed electrician.
Grounded Tools: Tools with Three Prong Plugs
Tools marked "Grounding Required" have a three
9
wire cord and three prong grounding plug. The
plug must be connected to a properly grounded
8
outlet (See Figure A). If the tool should electrically
malfunction or break down, grounding provides a
low resistance path to carry electricity away from
the user, reducing the risk of electric shock.
The grounding prong in the plug is connected
through the green wire inside the cord to the
grounding system in the tool. The green wire in the
cord must be the only wire connected to the tool's
grounding system and must never be attached to
an electrically "live" terminal.
Your tool must be plugged into
an appropriate outlet, properly
installed and grounded in accord-
ance with all codes and ordinances.
The plug and outlet should look like
those in Figure A.
Double Insulated Tools:
Tools with Two Prong Plugs
Tools marked "Double Insulated" do not require
grounding. They have a special double insula-
tion system which satisfi es OSHA requirements
and complies with the applicable standards of
Underwriters Laboratories, Inc.,
the Canadian Standard Asso-
ciation and the National Elec-
trical Code. Double Insulated
tools may be used in either of
the 120 volt outlets shown in
Figures B and C.
EXTENSION CORDS
Grounded tools require a three wire extension
cord. Double insulated tools can use either a two
or three wire extension cord. As the distance from
the supply outlet increases, you must use a heavier
gauge extension cord. Using extension cords with
inadequately sized wire causes a serious drop in
voltage, resulting in loss of power and possible tool
damage. Refer to the table shown to determine the
required minimum wire size.
The smaller the gauge number of the wire, the
greater the capacity of the cord. For example, a 14
gauge cord can carry a higher current than a 16
gauge cord. When using more than one extension
cord to make up the total length, be sure each cord
contains at least the minimum wire size required.
If you are using one extension cord for more than
one tool, add the nameplate amperes and use the
sum to determine the required minimum wire size.
Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be
sure it is marked with the suffi x "W-A" ("W" in
Canada) to indicate that it is acceptable for outdoor
use.
• Be sure your extension cord is properly wired
and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a
qualifi ed person before using it.
• Protect your extension cords from sharp objects,
excessive heat and damp or wet areas.
Recommended Minimum Wire Gauge
For Extension Cords*
Fig. A
Nameplate
25'
Amperes
0 - 2.0
18
2.1 - 3.4
18
3.5 - 5.0
18
5.1 - 7.0
18
7.1 - 12.0
16
12.1 - 16.0
14
16.1 - 20.0
12
* Based on limiting the line voltage drop to fi ve volts at
150% of the rated amperes.
READ AND SAVE ALL
Fig. B Fig. C
INSTRUCTIONS FOR FUTURE USE.
5
Extension Cord Length
50'
75'
100'
150'
18
18
18
16
18
18
16
14
18
16
14
12
16
14
12
12
14
12
10
--
12
10
--
--
10
--
--
--

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

6276-21

Table des Matières