TEST
Clean the parts of the freezer with lukewarm water on a soft cloth or with
a neutral detergent and with clear water, then wipe them dry.
Notes: Electric parts of the freezer can only be wiped by dry cloth.
Turn the thermostat knob on the middle position and turn on electricity.
The compressor and the light inside the freezer begin to work.
Close the door and wait 30 minutes. If the temperature in the freezer
compartment decreased obviously, it shows that the freezing system
works well. When the freezer operates for a period of time, the
temperature controller will automatically set the temperature on
conditions that the door is not too often opened.
If the above steps are successful, the trial operations are finished. The
freezer works normally.
TEMPERATURE CONTROL
The temperature in the freezer is controlled by the thermostat control
regulator in the upper the freezer. Turn the thermostat control regulator
with key attached up or down to regulate the temperature inside the
freezer. The markings on control regulator indicated the "Min, Max" for
the different temperature grades. The temperature decreases with
position MIN being the warmest and position MAX being the coldest.
Set the control to the middle position for normal use, but you may set the
control to other positions of you find the middle is too cold or too warm.
ALARM: Extensive temperature indicator
POWER: Electrical power indicator
SUPER: Super freeze indicator
SUPER FREEZE: Super freeze button
Super Freeze (Button)
If you need the temperature inside freezer to drop quickly, please
press the button and the indicator of Super will be on. The
appliance runs in SUPER FREEZE.
If you need the model to stop the function of SUPER FREEZE, please
repress the button and the indicator of SUPER will be off.
-22-