Contents
1. Safety Precautions ........................................... 2
Disposal of the Unit......................................................... 2
2. Introduction....................................................... 3
Overview of the System .................................................. 3
How the Heat Pump Works............................................. 3
Economical Best Practice ............................................... 4
Overview of Controls ...................................................... 4
3. Your Heating System........................................ 5
..................................................... 5
Important Parts of the Units - Points to Note .................. 5
...................................................... 6
4. Customising Settings for Your Home............. 7
Main Controller ............................................................... 7
General Operation .......................................................... 8
Changing Initial Settings ................................................. 8
Schedule ......................................................................... 9
Holiday Mode ................................................................ 10
Heating Mode ............................................................... 10
Domestic Hot Water (DHW) / Legionella Prevention .....11
Service Menu ................................................................ 12
5. Service and Maintenance............................... 13
Troubleshooting ............................................................ 13
Maintenance ................................................................. 13
Abbreviations and glossary
Abbreviations/Word
Description
Ambient temperature
The outdoor temperature
Freeze stat. function
Heating to prevent water pipes freezing
ASHP/HP
Air source heat pump
COP
Cylinder unit
Indoor unvented DHW tank and component plumbing parts
Hydrobox
Indoor unit housing the component plumbing parts and a plate heat exchanger
DeltaT
Difference in temperature between two variables
DHW mode
Domestic hot water heating mode for showers, sinks, etc
Flow rate
Speed at which water circulates around the primary circuit
Flow temperature
Temperature at which water is delivered to the primary circuit
FTC3
Flow temperature controller, the circuit board in charge of controlling the system
Compensation curve mode
Space heating incorporating outdoor temperature compensation
Heating mode
Space heating through radiators or UFH
Legionella
Bacteria potentially found in plumbing, showers and water tanks that may cause Legionnaires disease
LP mode
Legionella prevention mode – a function on systems with tanks to prevent the growth of legionella bacterium
Packaged model
Plate heat exchanger in the outdoor heat pump unit
Refrigerant
A compound used within the heat cycle that goes through a phase change from gas to liquid
Split model
Plate heat exchanger in the indoor unit
TRV
Thermostatic radiator valve – a valve on the entrance or exit of the radiator panel controlling the heat output
UFH