c) Push FUNC key again, the display will show the control output
value, the two points as shown in Fig 10 are lit.
The value of the MAIN control output is shown on the two
most significant digits, while the value of the SECONDARY
control output is shown on the two least significant digits.
N O T E S :
N O T E S :
N O T E S :
N O T E S :
N O T E S :
1) The graphic symbol "
"shows that the respective
output value is 100%.
2) If the control output is disabled the display will show OFF.
N O T E S
N O T E S :
N O T E S
N O T E S
N O T E S
a) The alternative displays are bound to the time out .To remove
the timeout press
or
.
b) When the LBA alarm is detected the indication described at
point a) is automatically forced. In this case the type of display
is not subject to timeout.
6 . 3
6 . 3
6 . 3 Indicators
Indicators
Indicators
Indicators
(beacons)
(beacons)
(beacons)
6 . 3
6 . 3
Indicators
(beacons)
(beacons)
There are three luminous indicators on the left side of the display.
ST
Flashes when the first phase of the SMART algorithm is
working (TUNE).
ON when the second phase of the SMART algorithm is
working (ADAPTIVE)
1
ON when output 1, used as control output, is ON, or
when alarm 1 is in alarm state.
2
ON when output 2, used as control output, is ON, or
when alarm 2 is in alarm state
6 . 4
6 . 4
6 . 4 How
6 . 4
6 . 4
How
How
How
How
to
to
to
to
to
check
check
check
check
check
or
or
or
or
or
modify
modify
modify
modify
modify
the
the
the
the
the
p a r a m e t e r s
p a r a m e t e r s
p a r a m e t e r s
p a r a m e t e r s
p a r a m e t e r s
When the instrument is in normal display mode check or modify
the operating parameters as follows:
1) Press the FUNC
FUNC
FUNC
FUNC key to advance the parameters (REV to go
FUNC
backwards); the display will show the mnemonic code of the
parameter and its value (or state) alternately.
2) To vary the value or the state, press the
or
case of a numerical value press
to increase,
fks-MK1-1-A0.pmd
13
3) Press the FUNC
FUNC
FUNC
FUNC
FUNC key to save the new value (or the new state)
and go to the next parameter. Press REV
previous parameter without saving the new value.
4) One can quit the modification/check of the operating
parameters:
- automatically, after the timeout (see note c)
- manually, pressing the FUNC
FUNC. key several times.
FUNC
FUNC
FUNC
N O T E S
N O T E S :
N O T E S
N O T E S
N O T E S
a) In relation to the instrument configuration, a few parameters
may not be displayed.
b) With the exception of the set point and the alarms ("SP","n.rST",
"AL.1" and "AL.2", see "P18" in section 5.2), the remaining
parameters can only be modified when the protection is
excluded.
The locked parameters are not displayed
The locked parameters are not displayed
The locked parameters are not displayed
The locked parameters are not displayed. . . . .
The locked parameters are not displayed
c) Checking and modifying the parameters are subject to timeout
(see "P17" in section 5.2). When this time has elapsed, the
instrument will return to the "normal display mode" and any
modifications of the last parameter displayed will be lost.
6 . 5 Operating
6 . 5
6 . 5
Operating
Operating
Operating
parameters
parameters
parameters
6 . 5
6 . 5
Operating
parameters
parameters
S P
S P
S P
S P
S P

Set Point

Set Point
Set Point
Set Point
Set Point
This parameter is available if at least one control output has been
configured.
Range:
da rL a rH
operative
operative
operative
operative
operative
n . r S t
n . r S t
n . r S t
n . r S t
n . r S t
Manual alarm reset
Manual alarm reset
Manual alarm reset
Manual alarm reset
Manual alarm reset
This parameter is available if at least one alarm has the manual
reset function.
Range:
On
= function active
keys (in the
OFF
= no action
to decrease).
N O T E
N O T E :
N O T E
N O T E
N O T E
- To reset the alarm condition select ON
GB
13
09/05/2006, 15.06
REV to display the
REV
REV
REV
ON then press FUNC
ON
ON
ON
FUNC
FUNC
FUNC. . . . .