MASTER MODELS - 5 poles M12 Secondary connector.
PIN
COLOUR
Brown
1
Blue
3
Grey
5
White
2
Black
4
MASTER MODELS - 8 poles M12 Primary connector.
STANDARD MODELS - 8 poles M12 connector.
PIN
COLOUR
NAME
Brown
24VDC
2
Blue
0VDC
7
Red
PE
8
White
OSSD1
1
Green
OSSD2
3
SEL_A
Grey
5
Pink
SEL_B
6
Yellow
K1_K2
4

WARNINGS REGARDING THE CONNECTION CABLES

12
NAME
TYPE
24VDC
-
0VDC
-
PE
-
SLAVE1
INPUT
SLAVE2
INPUT
TYPE
DESCRIPTION
-
+24VDC power supply
-
0VDC power supply
-
Ground connection
OUTPUT
Safety static outputs
OUTPUT
INPUT
Barrier configuration
INPUT
External contactors
INPUT
For connections over 50 m long, use cables with a conductor cross-section
2
of 1 mm
.
The power supply to the light curtain / light grid should be kept separate from
that to other electric power equipment (electric motors, inverters, frequency
converters) or other sources of disturbance.
Connect the Emitter and the Receiver to the ground outlet.
DESCRIPTION
+24VDC power supply
0VDC power supply
Ground connection
SLAVE OSSD outputs
readout
Table 4
According the normative EN61131-2
(ref. Par. "Configuration and operation
Feedback
Table 5
FUNCTIONING
-
-
-
According the normative
EN61131-2
(PNP active high)
FUNCTIONING
-
-
-
PNP active high
modes")