7. Slip the compression sleeve and compression nut on the
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw compression nut
onto outlet end with adjustable wrench. Do not overtighten or
you may crush the copper tubing.
8. Place the free end of the tubing in a container or sink, and turn
ON the main water supply. Flush the tubing until water is clear.
Turn OFF the shutoff valve on the water pipe.
Connect to Refrigerator
Depending on your model, the water line may come down from
the top or up from the bottom. Follow the connection instructions
for your model.
Style 1
1. Remove the plastic cap from water supply connection. Place
brass nut and compression sleeve on copper tube end as
shown.
A. Brass nut
B. Compression sleeve
2. Place end of the copper tubing into the plastic water valve
supply line. Slide the brass nut over the sleeve and screw the
nut into supply line.
3. Using an adjustable wrench, hold the nut on the plastic water
line to keep it from moving. Then, with a second wrench turn
the nut on the copper tubing counterclockwise to completely
tighten. Do not overtighten.
4. Check connection by pulling on the copper tubing.
5. Fasten the plastic water line to the refrigerator with a "P"
clamp. Slide the plastic water line into the retainer.
A. Brass nut
B. Compression sleeve
6. Turn on water supply to refrigerator and check for leaks.
Correct any leaks.
A
B
A
B
C
C. "P" clamp
Style 2
1. Remove plastic cap from water valve inlet port. Attach the
copper tube to the valve inlet using a compression nut and
sleeve as shown. Tighten the compression nut. Do not
overtighten. Confirm copper tubing is secure by pulling on the
tubing.
2. Create a service loop with the copper tubing. Avoid kinks
when coiling the tubing. Fasten the copper tubing to the
refrigerator cabinet with a "P" clamp.
A
B
C
D
A. Copper tubing
B. "P" clamp
3. Turn on water supply to refrigerator and check for leaks.
Correct any leaks.
Complete the Installation
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Plug into a grounded 3 prong outlet.
2. Flush the water system. See "Water and Ice Dispensers."
C. Compression nut
D. Compression sleeve