Figure 1: Location of the acoustic
axis
Figure 2: Type of cable needed if
unbalanced source is used (ex-
ample shown is RCA output to the
XLR input)
The controls are "Treble Tilt", "Bass Tilt" and "Bass
Roll-Off". An acoustic measuring system such as
WinMLS or comparable is recommended for ana-
lyzing the effects of the adjustments, however,
careful listening with suitable test recordings can
also lead to good results. Table 1 shows some
examples of typical settings in various situations.
Figure 4 shows the effect of the controls on the
anechoic response.
Treble Tilt
Treble Tilt control (switch 1) attenuates the tre-
ble response of the loudspeaker at frequencies
above 5 kHz by 2 dB, which can be used for
smoothening down an excessively bright sound-
ing system.
WARNING
ELECTRIC SHOCK HAZARD. DO NOT OPEN. DO NOT SUBJECT
TO WATER OR MOISTURE. NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
USE EARTHED MAINS CONNECTION ONLY.
AVERTISSEMENT
RISQUE DE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PAS
EXPOSER À L'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À
L'INTÉRIEUR REMPLAÇABLE PAR L'UTILISATEUR. ADRESSER
TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ. CET
APPAREIL DOIT ÊTRE RACCORDÉ À LA TERRE.
ON
OFF
BASS AND TREBLE TILT
BASS ROLL-OFF
TREBLE TILT -2dB
dB
dB
ALL OFF
ALL OFF
BASS ROLL-OFF -6dB 85Hz
0
0
3
1
-2
4
BASS TILT -2 dB
-4
3+4
-6
2
-6
BASS TILT -4 dB
BASS TILT -6 dB
65
2k
5k
20k
65 85
500 Hz
MAINS INPUT
ON
OFF
50 / 60 Hz 50 W 230 V~
IN
2
1
8020C BI-AMPLIFIED
3
MONITORING SYSTEM
-
+
GND
MAGNETICALLY SHIELDED
MADE IN FINLAND
www.genelec.com
SERIAL NUMBER
Figure 3: Control and connector layout on the rear panel
of an 8020C.
Bass Tilt
Bass Tilt control offers three attenuation levels
for the bass response of the loudspeaker below
2 kHz, usually necessary when the loudspeakers
are placed near a wall or other room boundaries.
The attenuation levels are -2 dB (switch 3 "ON"), -4
dB (switch 4 "ON") and -6 dB (both switches "ON").
Bass Roll-Off
Bass Roll-Off (switch 2) activates high-pass filter-
ing at 85 Hz to complement the low-pass filters of a
Genelec 7050 subwoofer. This switch should always
be set to "ON" when using the 8020C with these
subwoofers.
The factory setting for all tone controls is "OFF"
to give a flat anechoic response. Always start ad-
REFLEX PORT
THREADS FOR
CEILING AND
WALL MOUNTS
TONE CONTROLS
CONNECTOR PANEL
AND POWER SWITCH
(HORIZONTAL)
Iso-Pod™ TABLE
STAND
English 3