Pressure cell is faulty
Connecting hose from the pressure cell to the
waste gas collector is faulty, kinked or not con-
nected
The combustion air supply is obstructed
14.3. Alarm PELLET TEMP.
This occurs if the temperature of the pellet sensor
reaches a temperature that is too high.
The cause analysis must always be conducted by a
specialist.
Possible causes:
The rate of delivery of the pellets is too high in
the highest power setting.
Reduce the pellet quantity in the MAXIMALE
menu "(section 10.4.11)
The setting of the convection fan is too low. Not
enough heat is channelled to the installation
room.
Increase the speed of the convection fan in
the MAXIMALE menu (Section 10.4.11)
The convection fan outlet is obstructed.
The chimney draft is too high.
14.3. Alarm SMOKE FAN
This occurs in the event of an operational fault of the
smoke blower.
14.3. Alarm PELLET PROBE or
Alarm SMOKE PROBE
This occurs if one of the sensors is faulty.
14.4. Alarm BLACK OUT
This occurs if the power supply is interrupted for
more than 20 seconds.

15. Cleaning

In order for the unit to function perfectly, it is abso-
lutely necessary to continually clean the combustion
chamber and the ash box.
This cleaning must always be carried out when
the unit is cold.
Only use a suitable ash vacuum cleaner.
Check the connector at regular intervals for a
possible build-up of soot and ash.
Clean the glass pane with a special glass cleaner
or oven spray. Do not use any abrasive materi-
als.
Pull out the combustion pan
15.1 Function CLEAN STOVE
This function makes it possible to clean the unit with-
out ashes escaping into the installation room as a
result of underpressure caused by the movement of
the door.
Press the OFF button for 2 seconds.
The flue gas fan will run at maximum speed,
which causes underpressure in the combustion
compartment so that the ashes do not escape
out of the combustion compartment.
It switches off automatically at the end of the
operation.
The function can be interrupted by pressing the
OFF button.
15.2 Complete cleaning
The unit must be completely cleaned at least month-
lyeach heating season.
Here, in addition to the cleaning measures already
described, the back wall of the combustion chamber
must be removed and the flue gas ducts that are
behind must be cleaned.
Please proceed as follows:
Pull out the combustion pan.
Lift up the back wall, pull it forward to the door
and then take it out of the unit to the front.