To exit the menu:
Press the OFF button to exit the KEYLOCK)
menu.
Press the OFF button to exit the SET STOVE
menu.
To activate or deactivate the BLOCK BUTTONS
function, press the ON and OFF buttons simulta-
neously.
10.4.9 RESET
This resets all operator entries in the SET STOVE-
menu to their factory settings.
Operator settings like the heating power, convection
fan output and room temperature are maintained.
Press the two arrow buttons
same time.
The message MENÜ SET WORK appears on the
display.
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
Press the ON button to get into the menu.
Hold the
button down until the message
RESET appears.
Press the ON button to arrive at the menu.
The current setting NEIN (NO) will flash.
Use the
+
buttons to select YES or NO.
Press ON to confirm.
After confirmation of the YES option, the DONE mes-
sage appears.
To exit the menu:
Press the OFF button to exit the RESET menu.
Press the OFF button to exit the SET STOVE
menu.
10.4.10 ECONOMY
This makes it possible to reduce the maximum power
setting with the Automatic A heating power setting of
5 to 1-4.
Press the two arrow buttons
same time.
The message MENÜ SET WORK appears on the
display.
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
Press the ON button to get into the menu.
Hold the
button down until the message
ECONOMY appears.
Press the ON button to arrive at the menu.
The current heating power setting will flash.
Use the
+
buttons to change the maxi-
mum heating power setting.
+
at the
+
at the
- 26 -
Press ON to confirm.
To exit the menu:
Press the OFF button to exit the ECONOMY
menu.
Press the OFF button to exit the SET STOVE
menu.
10.4.11 INSTALLER
In the Installer menu, the following parameters can
be adjusted by ± 27 % for the lowest and highest
heating levels:
pellet quantity
speed of exhaust fan
speed of convection air fan
Press the ON +
The message MENÜ WERK appears on the
display.
Press the
button 1 time.
The message INSTALL appears on the display.
Press the ON button to arrive at the menu.
Enter the password 201 using both two arrow
keys and confirm with ON.
The message MENÜ MINIMAL appears on the
display.
With the
button, the MENÜ MAXIMALE menu
(highest heating level) can now be selected.
In order to enter the selected menu, press the
ON button.
Use the arrow keys to select the menu PELLET
MIN., ABGASVENT. MIN or LUFTVENT. MIN.
In order to enter the selected menu, press the
ON button.
The percent display flashes.
Enter the desired percentage change using both
two arrow keys and confirm with ON.
The same parameters can be changed for the
highest heating level in the MAXIMALE menu.
To exit the menu:
Press the OFF button 3x to exit the menus.
To reduce the air noise, the speed of the convection
fan can be reduced in the MAXIMALE menu. To
make sure the monitored pellet temperature does not
become too high, the device automatically switches
over to the maximum speed in intervals. The mes-
sage "E" then appears on the display.
You can find further information on "What do I adjust
and when" in section 14 "Alarm Messages".
buttons at the same time.