11. Display hours of operation
The hours of operation can be displayed in the top
menu level.
Press the button
Press the button
12. Display operating data
All the current operating data can be retrieved here,
for example the software version, flue gas tempera-
ture, heating power setting, etc.
Press the OFF +
Use the
+
buttons to select the individual
parameters.
The following parameters are displayed:
-
Unit model – software version
-
Starting time
-
Flue gas temperature
-
Room temperature
-
Room target temperature
-
Pellet temperature
-
RPM of flue gas fan
-
Air speed
-
Heating power level 01=P1/04=P2/08=P3/
-
Screw conveyor (rotating time <8.0")
-
Resistance (ignition element)

13. Remote control

The delivery contents of the unit include a remote
control.
This is an infrared remote control. You must therefore
point it at the receiver unit on the back of the unit to
operate it.
If the reception is not optimum, then please change
the position of the receiver from horizontal to vertical.
Make sure that the sensor points to the centre of the
room.
= Display of the hours of
operation so far
= Display the hours of
operation until the next
special service
buttons at the same time.
012=P4/016=P5
The following unit settings can be made with the re-
mote control:
Start ignition process
Switch off
Change heating power setting P
Change convection fan setting V
The change to the heating power and convection fan
setting will be indicated by means of an acoustic
signal. If level A is selected (= Automatic), the signal
sounds 3x.
The control lamp of the remote control flashes when
the buttons are pressed.
a
Ignition
Press buttons 1 and 3 at the same time.
Switch off
Press buttons 2 and 4 at the same time.
Change heating power
Press one or both of the buttons that are marked
- 27 -