Heraeus Signum metal bond Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Dispense an ample amount of Signum metal bond I into a mixing dish. Apply to the prepared
surface with a fine brush and allow to air dry. Apply a second coat if necessary.
Shake Signum metal bond II well to attain an optimal distribution of the colour pigments on the
surface during application. Apply 1–2 uniform layers of Signum metal bond II with another
brush and polymerize for 90 sec. with the Heraflash, HiLite power or UniXS. For intraoral use
polymerize Signum metal bond II for 40 seconds with a dental polymerization lamp (e.g. Trans-
lux Power Blue).
For an optimum bond apply the relevant opaquer without undue delay and without contami-
nating the surface by touching it. Then apply the composite or acrylic.
Instructions and contraindications:
Only for use by dentists and dental technicians for the above indications.
Close the Signum metal bond I and II bottles immediately after use.
Signum metal bond II should not cover the surface completely. The shade is masked by the
application of Signum opaque F.
Hazard/Safety information:
Store Signum metal bond I + II at room temperature (max. 25°C (77°F)).
The product is highly flammable. Keep away from naked flames, sources of ignition and direct
sunlight.
The product can irritate the eyes, respiratory organs and skin. On contact with the eyes or
skin, immediately rinse thoroughly with water and consult a doctor.