The parameter and values have the following meaning:
Description
T1
,Moisture measurement' - Time in seconds
T2
,Active drying' interval between 2 measurements of
moisture - Time in seconds
T3
,Subsequent drying' - Time in hours
T4
,Active drying' - Time in hours
HT
Relative humidity in % which must be exceeded in order
for the subsequent drying to begin.
HD
Maximum allowable difference in % between space
and process air in g water / kg air
TD
Sending interval - Time in seconds
MR
Treshold value mixing ratio multiplied
with 10 in g water / kg air
When a value has been misspelled or the value en-
tered is outside the range values, the default value is
used automatically.
Comments:
• On each abbreviation must be a ':' and then the
selected value
• A line must have only one parameter, and seperat-
ed by a ':', the corresponding value
• The order of the parameters is arbitrary
• A value of 100 for the parameter MR means 10 g
water / kg air
Method:
• Connect the USB stick with the USB interface of
the DA 4
• Now the file is loaded from the usb stick and the
configuration gets stored on the device-board
• The file is not deleted from USB stick, but the
configuration contained therein is read each time
again for a restart
B - 6
• When the USB stick which is connected to the de-
The display shows the subsequent drying (E). The-
subsequent drying has been completed. The moisture
values are recorded in intervals only. However, not
every channels is meaured individually, but a common
value from all three channels. This serves to conclu-
ding observation of the floor structure. Should the
moisture value measured increase three times during
this phase, the drying starts again.
• Remove the humidity sensor from the compressor,
• Store the air sensor at the Discharge Control Unit .
• Store the antenna with the antenna cable at the DA
• Remove the hose connections.
Operating manual – DA 4 / DA 4 M Discharge Control Unit
Minimal value
Maximum value
20
60
4
4
50
1
300
10
vice contans no DA4.CFG file, the default values
are used during the drying.
06. DECOMMISSIONING
and store it in the holding bracket of the Discharge
Control Unit .
4 M Discharge Control Unit again.
Preset value
65535
90
65535
600
240
48
240
96
80
70
40
20
65535
14400
800
100
EN