Remove the sticker from the appliance lid and archive
it in a secure place.
Operating range
The Discharge Control Unit has an air flow of up to
350 m³ / h and may work with vacuums of up to
250 mbar. This makes it suitable for work with the
majority of compressors and other components for re-
novation of water damage.
Please note that the Trotec Compressor VX5 is desi-
gned for a use up to 70 m² and the VE 4 for use up to
40 m². Install the unit separately in a suitable location
next to the core drilling holes (fig. 2).
Display
The display of the Discharge Control Unit DA 4 informs
you about
– past and present humidity and room measurements,
– the active selection and drying ducts,
– about the connection of the DA 4 with the USB flash
drive or mobile or web central.
1
5
4
Mixing ratio of the ambient air
1
1
Status indicator: S – send readiness (network found),
2
M – modem recognized, U – USB stick recognized
Channel indocator
3
3
Current function or warning alert
4
Measurement results of channels / mixing ratios
5
5
(Illustration 3.1: Display screen)
1
2
Relative humidity and temperature of the ambient air.
1
Measurement results of channels / relative humidity
2
(Illustration 3.1: Display screen)
B - 5
3
2
Operating manual – DA 4 / DA 4 M Discharge Control Unit
MultiMeasure Studio
We recommend using our "MultiMeasure Studio" soft-
ware. The scope of delivery of the Discharge Control
Unit includes the standard version of MultiMeasu-
re Studio, which includes all our basic functions and
is available for download on our website. By means
of this software, you can easily record, analyse and
evaluate the generated USB data. You can comfortably
create protocols of measurement data or use the data
as basis for creating offers and invoices.
Find out how to install MM Studio
or expand the basic version to
include interesting functions under
https://de.trotec.com/en/services/
overview-of-services/downloads/

05. TIMER CONFIGURATION

The interval times (moisture measurement 90 sec.,
active drying 10 min, and subsequent drying 4 hours)
as well as the difference in the mixing ratio between
the ambient air and the process air, can be configu-
red via usb stick.
On the USB stick must be a text file with the name
DA4.CFG and must be saved to the following content:
T1: 90
T2: 600
T3: 48
T4: 96
HT: 70
HD: 20
TD: 14400
MR: 100
EN