Connection As A Group Controller - Becker Centronic VarioControl VC520 Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour Centronic VarioControl VC520:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Assembly and Operating Instructions

Connection as a group controller

Caution
• Risk of injury by electric shock.
• Must be installed by an authorised electrician!
• Only the back of the hand is protected by the device. No protection
against accidental contact!
• Do not bend, shorten or add extensions to the antenna.
• The programming button must be operated with an insulated tool .
• The switched current of the device must be observed at all times.
1. Connect the VC520 as follows:
2. Programme one transmitter into the receiver (see section "Programming ra-
dio channels")
3. Secure the device in the box.
Note
Ensure that optimum radio reception is achieved.