Switching Off - Italkero lightfire dolce vita 12 kW Instructions D'installation Et D'utilisation

Décoratif extérieur chauffage au gaz
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SWITCHING OFF

A - MANUAL mod.:
1 – Remove the side cover (Fig. 3: 13).
2 – Turn the control knob clockwise, returning this to position "0" (Fig. 5: 1).
3 – Correctly fit the side cover back on in reverse sequence.
B – REMOTE CONTROL Mod.:
1 – Press the ON/OFF button on the remote control (Fig. 6) or on the control unit on board the
appliance (Fig. 6).
2 – Remove the side cover (Fig. 3: 13) and close the gas supply tap.
IMPORTANT! IF THE APPLIANCE IS NOT USED FOR A LONG PERIOD, REMOVE THE
IGNITION BATTERIES (Fig. 4: 3), OF THE REMOTE CONTROL AND OF THE REMOTE
CONTROL UNIT (Fig. 4: 3) FROM THEIR HOUSING, TO PREVENT CORROSIVE LIQUID
LEAKING OUT AND CAUSING DAMAGE.
MAINTENANCE
IMPORTANT! BEFORE PERFORMING ANY TYPE OF MAINTENANCE, MAKE SURE THE
GAS SUPPLY TAP AND/OR BURNER SUPPLY TAP ARE CLOSED.
REPLACING THE BOTTLE
1 - Make sure the appliance is completely cold;
2 - Remove the tank cover side panel (Fig 3: 15);
3 - Remove the cylinder from the cylinder holder;
4 - Disconnect the pressure regulator from the cylinder valve;
5 - Check the state of efficiency of the gas supply pipe visually (presence of cracks) and
checking the expiration date stamped;
6 - Check the efficiency of the regulator while verifying the presence and condition of the seal
gas (if replacement is recommended at each change cylinder);
7 - Connect the new bottle and store it in the compartment;
8 - Check the perfect gas circuit with soapy water or specific products;
9 - Replace the side panel.
IMPORTANT! After replacement of the cylinder, the first attempts at ignition may occur with lon-
ger times due to the possible presence of air in the pipeline.
Maintenance concerns:
Cleaning the inside of the glass pipes: use a non-metal pipe-brush (optional) to remove traces
of dirt and/or soot.
IMPORTANT! Dry clean with a soft cloth. The use of liquid products could create depo-
sits and/or encrustations that are hard to eliminate.
- Cleaning the outside of the appliance (use a soft cloth and neutral cleaning products and
avoid pouring these directly on the part to be cleaned).
- Control or replacement of the rubber gas hose (max L = 1.5m), whenever damaged and
according to the schedule provided by Laws and Standards applicable in the Country of use.
- Checking the integrity of all the parts making up the appliance; in case of wear or breakage,
only replace with the Manufacturer's original spare parts.
- replacing batteries for electronic ignition (Fig. 4: 3) or in the Remote Control unit (Fig. 4: 3).