Sommaire des Matières pour De Dietrich C230-Kit propane 80/120 kW
Page 1
Assembly instructions Instructions de montage C230-Propane kit 80/120 kW C230-Kit propane 80/120 kW Before installing, first read the additional safety instruction for USA and Canada which is included with this part. Avant installer, lisez les instructions de securite supplementaires pour Canada et les Etats Unis. Le document a ete ajoute a cette de piece.
Page 2
WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
Page 4
Convert boiler as per instructions Set (starting, full load, low load) speeds to the correct value (see table) Adjust the boiler to the correct CO level (see table) setting values for propane (G31) at low load Boiler type Fan speed (rpm) Control Setting Control margin...
Page 5
Assemblez la chaudière selon les instructions Réglez (démarrage-grande allure-petite allure) les rotations sur la valeur correcte (voir tableau) Ajustez la chaudière sur le CO correct (voir tableau) Valeurs de réglage O pour propane (G31) à petite allure Type de chaudière Vitesse de rotation Marge de Marge de Marge de...