Operating Instructions
Balancer
040874-...x2,0
5
Montage of the balancer
Fasten the cap (11) with the screw (1) and the washer (36) on the balancer.
Turn the screw (9) clockwise.
Thereby the gear-wheel (19) and the drum (27) operate the coiling of the wire (28).
Make sure that the wire is coiling into all the slots of the drum (27) one after another without superposition.
When the load approaches the min. load capacity of the balancer, the reaction moment "M.R." of the spring operates the axial
movement of the screw (9), compressing the spring (8), and in that way also the safety device (13), until the position H2 has been
reached (drawing G2)
Turn the screw as far as the required load capacity has been reached.
To reach the middle load capacity of the balancer the following approx. number of screw (9) turns are necessary:
For 040874-014X2,0 n. 90 turns
For 040874-018X2,0 n. 50 turns
For 040874-022X2,0 n. 130 turns
For 040874-025X2,0 n. 120 turns
All repair works must be executed through a skilled and authorised specialist.
In case of doubt, ask Company Conductix-Wampfler.
6
Characteristics
Order number
040874-014x2,0
040874-018x2,0
040874-022x2,0
040874-025x2,0
BAL0400-0072a-D/E/F
www.conductix.com
Load capacity (kg)
10 - 14
14 - 18
18 - 22
22 - 25
Cable travel (m)
2,0
2,0
2,0
2,0
Weight (kg)
5,5
6,0
6,5
6,5